4.3 振動步進應力試驗
振動步進應力是在環境溫度下+20°C進行。
在測試的產品進行振動步進應力始終在設定點5GRMS的振動值,增加5GRMS的增量,10分鐘的停留時間間隔。30GRMS后,振動下降到5GRMS,以確定是否發生了故障,不在更高的振動水平檢測。如果在這個共振振動的檢測沒有故障,振動增加到下一級。
振動步進應力試驗:
Setpoint (Grms) | Functional Test Result (Pass/Fail) | Notes |
0 | Pass | Sample no.2 was applied in this test. |
5 | Pass |
|
10 | Pass |
|
15 | Pass |
|
20 | Pass |
|
25 | Pass |
|
30 | Pass |
|
5 | Pass |
|
35 | Pass |
|
5 | Pass |
|
40 | Pass |
|
5 | Pass |
|
50 | Pass |
|
5 | Pass |
|
55 | Pass |
|
5 | Pass |
|
60 | Pass |
|
5 | Pass |
|
65 | Pass |
|
5 | Pass |
|
70 | Pass | The LED light panel kept flashing and the functional test items were not able to check as the value kept changing, but the LED light panel still can function and the test kept going. |
5 | Pass |
|
75 | Pass | The vibration operating limit and destruct limit was found at >75 Grms. |
5 | Pass |
|
在測試LED驅動器的過程中,在振動臺記錄的GRMS的振動水平。產品的響應的測量帶寬是從20Hz到5000 Hz。測量結果總結在表9。功率譜密度圖在測量頻段的能量光譜分布都包含在附錄B,過低的設定點水平(5GRMS和75GRMS)。
4.4 綜合環境應力試驗
該系統經過五次溫度循環,從60℃至+ 110 °C,平均熱轉化率70°C/每分鐘結合振動。振動開始設定點在15 GRMS,每個熱循環增量為15 GRMS。在每個極端溫度的停留時間為10分鐘。綜合環境應力試驗: